The Malaysian Communications and Multimedia Commission (MCMC) published that the Short-Range Devices (SRD) that operates in the frequency 5925–6425 MHz, including Wi-Fi 6E, would be approved after complying with the following aspects:
Option 1, Test report issued based on standard Draft ETSI EN 303 687 or any equivalent standard:
- Comply with the following Maximum Power:
- 25mW EIRP (for indoor and outdoor use)
- 200mW EIRP (for indoor use only)
- The test standard must be according to the scope of accreditation of the accredited laboratory. Otherwise, SIRIM must be a witness of the testing if the test standard is not covered in the testing laboratory’s scope of accreditation or, the testing is performed by a non-accredited laboratory.
Option 2:
The testing is performed at RF&EMC Testing Laboratory of SIRIM QAS International Sdn. Bhd.
Type Approval impacted? Yes, test reports
Spectrum Impacted: Yes, 5925–6425 MHz
Imports Impacted: No
Standards Impacted: No
Product Impact: SRDs